ri-champion smartPRO+ - Riester

ri-champion smartPRO+

ri-champion® smartPRO+

The Riester ri-champion® smartPRO+ is a clinically validated blood pressure monitor, designed for fast and reliable readings. Advanced performance with irregular heartbeat detection and averaging capabilities. Clinical accuracy for blood pressure monitoring both at home and in professional settings.

smartPRO+


ri-champion® smartPRO+ Bluetooth package with adult cuff W
ri-champion® smartPRO+ Bluetooth package with adult cuff S
ri-champion® smartPRO+ Monitor
Adult cuff W (Wide: 24 - 43 cm)
Adult cuff S (Small: 15 - 24 cm)

Features and Benefits

  • World class, clinical grade NIBP monitor
  • Arrythmia detection and clinically validated meeting standard EN1060-4, NIBP clinical investigation
  • Fast and quiet operation
  • 200 Measurements on one set of 4 AA batteries
  • Large easy to read backlit screen
  • CE / FDA Approved
  • Accuracy to ±3 mmHg or ±2% of reading
  • Irregular heartbeat detection
  • Averaging measurement function
  • IP21 Water ingress protection
  • Optional Bluetooth® connectivity
Specifications: ri-champion smartPRO+

System Performance

Power Four 1.5V AA alkaline batteries
Battery Life 200 readings
Size of Monitor w/o Cuff 141 (L) x 121 (W) x 72 (H)mm
Weight 350g without batteries
Cuff Sizes S (small) 15 – 24cm (5.9 – 9.4 inches) with air tube 80 cm W (Wide size) 24 – 43 cm (9.4 – 16.9 inches) with air tube 80 cm
Memory 400 records
Operating Conditions 5°C to 40°C (41°F to 104°F), 15% to 93% relative humidity, 700 hPa to 1060 hP
Storage / Transportation Conditions -25°C to 70°C (-13°F to 158°F), 10% to 95% relative humidity
IP Classification IP21

Power Management

Power Saving Automatic power off if system idle for 3 minutes
Power Supply Input DC + 6V / 1A (max) via Power Plug

Blood Pressure Measurement Performance

Heart Rate Range 40 – 199 beat per minute
Systolic Measurement Range 60 mmHg – 255 mmHg
Diastolic Measurement 30 mmHg – 195 mmHg
Pulse Rate Measurement Range 40 – 199 beats / minute
Maximum Inflation Pressure 280 mmHg
Accuracy of Pressure ±3 mmHg or ±2% of reading
Accuracy of Pulse rate ±4% of reading
Measurement Unit Either mmHg or KPa

Electrical and Safety Standards

This device has been tested to meet the electrical and safety requirements of: IEC/ EN 60601-1, IEC/EN 60601-1-2, EN 301 489-17, EN 301 489-1, EN 300 328.

Reference to Standards

  • EN 1060-3, NIBP-requirements
  • IEC60601-1 General requirement for safety
  • IEC60601-1-2 Requirements for EMC
  • EN1060-4, NIBP clinical investigation
  • AAMI / ANSI / IEC 80601-2-30, ANSI/AAMI/ISO 81060-2, NIBP requirements

Inquiry about

Accept Terms and Conditions
ri-champion smartPRO+
ri-champion smartPRO+

You Recently Viewed Items

Events / Shows View all

Reunión virtual con el Dr. Julian Triviño (Colombia)
Reunión virtual con el Dr. Julian Triviño (Colombia)

Reunión virtual con el Dr. Julian Triviño (Colombia)

5555 NW 74 AVE.
MIAMI. FL. 33166
P: 305-882-0120
F: 305-882-0140
info@mercoframes.com
alan@mercoframes.com
WhatsApp +1 305-882-0120
Hangouts alan@mercoframes.net