Fully Automatic, Non Contact Tonometer with Pachymeter TX-20P - CANON

Fully Automatic, Non Contact Tonometer with Pachymeter TX-20P

With fully automated 3D alignment and a built-in pachymeter the TX-20P is more than just a tonometer

A Fully Automatic, Non Contact Tonometer combined with a Pachymeter. The TX-20P is a multi-functional ophthalmic instrument that measures IOP and Central Corneal Thickness and then automatically calculates the corrected IOP.

Benefits

  • Fully Automatic, Non Contact Tonometer combined with a Pachymeter
  • Advanced intelligent 3D fully automated operation
  • Just press the button
  • Extremely accurate
  • More than just a very accurate Tonometer
  • Fast and timesaving
  • Space saving
  • Excellent ergonomics
  • Patient friendly
  • Lower and upper IOP warning
  • Intelligent powered joystick

Key Features

TonometerTonometer
Tilting LCD ScreenTilting LCD Screen
PrinterPrinter
Auto 3D AlignmentAuto 3D Alignment
Auto TrackingAuto Tracking
Auto MeasurementAuto Measurement

Detailed Features

Fully Automatic, Non Contact Tonometer combined with a Pachymeter

The TX-20P is a multi-functional ophthalmic instrument that measures IOP and CCT and then automatically calculates the corrected IOP

Just press the button

No special skills required, just align on the pupil and the advanced intelligent automatic operation will take over. making the instruments very easy to use. The results will always be just as accurate , completely independent of the operator.

More than just a very accurate Tonometer

The CCT values can also be displayed together with the pachymetry image, so it could help to detect corneal abnormalities too

Space saving

No need for two devices, the TX-20P is one compact and sleek instrument.

Patient friendly

The soft airpuff and short examination time make the TX-20P very comfortable for the patient.

Intelligent powered joystick

For easy 3D alignment and initiating measurement

Corneal thickness is important because it can mask accurate readings of eye pressure and delay diagnosis of glaucoma. Thicker corneas overestimate IOP values and thinner corneas underestimate. With a growing number of patients having LASIK surgery, CCT compensation is becoming increasingly important in both diagnosis and appropriate treatment plans.

Advanced intelligent 3D fully automated operation

Simply initiate the examination and multiple IOP and CCT measurements of the right and left eye will be done completely automatically!

Extremely accurate

The TX-20P will automatically calculate the corrected IOP based on the CCT values. Since the measurements are done extremely fast, any movement of the patient will not influence the measurement accuracy.

Fast and timesaving

The TX-20P will align and measure extremely fast, even the print out and paper cut off are done automatically, reducing examination time.

Excellent ergonomics

The tilting 5.7” colour LCD screen makes it possible to operate the TX-20P while standing or sitting.

Lower and upper IOP warning

To assist during screening, threshold values can be changed to your requirements

Inquiry about

Accept Terms and Conditions
Fully Automatic, Non Contact Tonometer with Pachymeter TX-20P
Fully Automatic, Non Contact Tonometer with Pachymeter TX-20P

You Recently Viewed Items

Events / Shows View all

Reunión virtual con el Dr. Julian Triviño (Colombia)
Reunión virtual con el Dr. Julian Triviño (Colombia)

Reunión virtual con el Dr. Julian Triviño (Colombia)

5555 NW 74 AVE.
MIAMI. FL. 33166
P: 305-882-0120
F: 305-882-0140
info@mercoframes.com
alan@mercoframes.com
WhatsApp +1 305-882-0120
Hangouts alan@mercoframes.net